• Title of article

    Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods

  • Author/Authors

    Abdelrahman, Maha Mohamed Beni-Suef University - Faculty of Pharmacy - Pharmaceutical Analytical Chemistry Department, Egypt , Abdelaleem, Eglal Abdelhameed Beni-Suef University - Faculty of Pharmacy - Pharmaceutical Analytical Chemistry Department, Egypt , Ali, Nouruddin Wageih Beni-Suef University - Faculty of Pharmacy - Pharmaceutical Analytical Chemistry Department, Egypt , Emam, Raghda Abdelmoneim Beni-Suef University - Faculty of Pharmacy - Pharmaceutical Analytical Chemistry Department, Egypt

  • From page
    67
  • To page
    75
  • Abstract
    wo accurate, precise and sensitive RP-HPLC and HPTLC-Densitometric methods have been developed for the determination of Carbazochrome and Troxerutin in their binary mixture without previous separation. Method (A) is RP-HPLC which depended on isocratic elution using C18 column and mobile phase consisting of water containing (0.2% triethylamine (TEA), 1% tetrahydrofuran (THF)):methanol (65:35, by volume) at a flow rate of 1.5 mL min−1 and the effluent was monitored at 350 nm. Good resolution was obtained with tR values of 2.069 and 5.174 min for Carbazochrome and Troxerutin, respectively. Method (B) is HPTLC-Densitometric method, using silica gel 60 F254 HPTLC plates and methanol:chloroform:ammonia (40:60:7, by volume) as a developing system. The bands were scanned at 350 nm. The proposed methods have been validated as per ICH guidelines and their linearity was evident in the ranges of 0.25–10 and 5–50 μg mL^−1 for method (A) and 0.02–0.8 and 0.1–2 μg band^−1 for method (B) for Carbazochrome and Troxerutin, respectively. The developed methods have been applied for the determination of the above mentioned drugs in their pharmaceutical formulation where no interference from the excipients has been detected. Statistical comparison of the results obtained by the developed methods and those obtained by the reported HPLC methods showed no significant difference between them. The developed methods are sensitive, accurate and precise and can be easily used for quality control analysis of the studied drugs.
  • Keywords
    Carbazochrome , Troxerutin , RP , HPLC , HPTLC , Densitometry , Pharmaceutical formulation
  • Journal title
    Bulletin Of Faculty Of Pharmacy, Cairo University
  • Journal title
    Bulletin Of Faculty Of Pharmacy, Cairo University
  • Record number

    2696834