Title of article
Which Stapler Charge Is Safest for Performing Ileocolic Anastomoses ?
Author/Authors
Montuori, Mauro Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Pinotti, Enrico Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Cigagna, Luca Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Pitoni, Ludovica Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Pirovano, Riccardo Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Mauri, Gianmaria Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Vasino, Michele Ciocca Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy
Pages
5
From page
98
To page
102
Abstract
Ileocolic anastomoses are made using a mechanical stapler or via hand-sewing, with many
meta-analyses and reviews discussing their safety. This study compared two mechanical devices and charges,
namely Echelon Flex with white charge (2.6 mm) versus EndoGIA with blue charge (3.5 mm), in isoperistaltic
side-to-side ileocolic anastomosis after right hemicolectomy for cancer with similar surgical technique and
postoperative management.
Methods: We made a retrospective analysis of all right hemicolectomies for malignancies performed between
1 January 2014 and 31 December 2019 in our department, comparing the mechanical device and the stapler
charge used for the ileocolic isoperistaltic anastomosis.
Results: A total of 151 patients underwent right hemicolectomy for cancer. In 101 cases, the device used to
perform ileocolic side-to-side isoperistaltic anastomosis was Echelon Flex with white charge (2.6 mm). In
50, the device used was EndoGIA with blue charge (3.5 mm). There were no significant differences in the
baseline characteristics or complication rate (P=0.727). In particular, no differences were found in the rate of
anastomotic leakage (P=0.851) or anastomotic bleeding (P=0.218). The median length of stay was ten and seven
for the white and blue groups, respectively (P=0.112).
Conclusion: In our experience, mechanical ileocolic anastomosis is safe, and the two indicated staplers with
the described charges do not differ in terms of anastomotic leak or bleeding. We hope that this study will
motivate further investigations in this field.
Keywords
Stapler charge , Stapler , Colon cancer , Right hemicolectomy , Ileocolic anastomosis
Journal title
Iranian Journal of Colorectal Research
Serial Year
2021
Record number
2701487
Link To Document