    Montuori, Mauro Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Pinotti, Enrico Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Cigagna, Luca Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Pitoni, Ludovica Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Pirovano, Riccardo Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Mauri, Gianmaria Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy , Vasino, Michele Ciocca Department of Surgery - Policlinico San Pietro - Ponte San Pietro (BG), Italy

  • Pages
    5
  • From page
    98
  • To page
    102
  • Abstract
    Ileocolic anastomoses are made using a mechanical stapler or via hand-sewing, with many meta-analyses and reviews discussing their safety. This study compared two mechanical devices and charges, namely Echelon Flex with white charge (2.6 mm) versus EndoGIA with blue charge (3.5 mm), in isoperistaltic side-to-side ileocolic anastomosis after right hemicolectomy for cancer with similar surgical technique and postoperative management. Methods: We made a retrospective analysis of all right hemicolectomies for malignancies performed between 1 January 2014 and 31 December 2019 in our department, comparing the mechanical device and the stapler charge used for the ileocolic isoperistaltic anastomosis. Results: A total of 151 patients underwent right hemicolectomy for cancer. In 101 cases, the device used to perform ileocolic side-to-side isoperistaltic anastomosis was Echelon Flex with white charge (2.6 mm). In 50, the device used was EndoGIA with blue charge (3.5 mm). There were no significant differences in the baseline characteristics or complication rate (P=0.727). In particular, no differences were found in the rate of anastomotic leakage (P=0.851) or anastomotic bleeding (P=0.218). The median length of stay was ten and seven for the white and blue groups, respectively (P=0.112). Conclusion: In our experience, mechanical ileocolic anastomosis is safe, and the two indicated staplers with the described charges do not differ in terms of anastomotic leak or bleeding. We hope that this study will motivate further investigations in this field.
  • Keywords
    Stapler charge , Stapler , Colon cancer , Right hemicolectomy , Ileocolic anastomosis
  • Journal title
    Iranian Journal of Colorectal Research
  • Serial Year
    2021
  • Record number

    2701487