Title of article
Numerical Investigation of a Hydrogen-fuelled Planar AP-SOFC Performance with Special Focus on Safe Operation
Author/Authors
Kamvar, Majid Department of Mechanical Engineering - Islamic Azad University Parand Branch, Parand, Iran , Steinberger-Wilckens, Robert Center for Fuel Cell and Hydrogen Research - School of Chemical Engineering - University of Birmingham, Edgbaston, UK
Pages
13
From page
113
To page
125
Abstract
The All-Porous Solid Oxide Fuel Cell (AP-SOFC) is a scheme that links a dual and
single chamber SOFC, combining the potential advantages of both. The AP-SOFC
is a novel concept that benefits from dual-chamber SOFC technology with a porous
electrolyte, which allows the tunned distribution of oxygen on the anode side that
allows the controlling of air and fuel distribution that is not possible in a single
chamber scheme of SOFC.
Intermixing of fuel and air in AP-SOFC systems could cause the formation of
explosive gas mixtures, especially when hydrogen is used as fuel due to its high
flammability in air mixture. Thus, the aim of this study is to investigate the safe
operation of a hydrogen-fuelled planar AP-SOFC using a two-dimensional finite
element method based numerical model. To achieve this goal, different combinations
of the hydrogen and oxygen inlet mole fraction are considered. Since a change in
the inlet mole fraction of hydrogen and oxygen can affect the cell performance, four
safe conditions for these combinations are chosen and compared. Finally, the best
combination of the inlet mole fraction of hydrogen and oxygen having both safe
operation and enhanced cell performance is reported.
Keywords
All porous , Solid oxide fuel cell , Hydrogen-fuelled , Safe operation , Porous electrolyte