Yousefi Kashi, Amir Shahram Department of Radiation Oncology - Shohada-e-Tajrish Hospital - Faculty of Medicine - Shahid Beheshti University of Medical Sciences, Tehran , Khaledi, Samira Department of Radiation Oncology - Shohada-e-Tajrish Hospital - Shahid Beheshti University of Medical Sciences, Tehran , Houshyari, Mohammad Department of Radiation Oncology - Shohada-e-Tajrish Hospital - Faculty of Medicine - Shahid Beheshti University of Medical Sciences, Tehran
Pages
4
From page
1
To page
4
Abstract
Background: Radiotherapy is the gold standard for treatment of prostrate cancer as it can cover an adequate area of tissues at risk
for metastasis.
Objectives:We evaluated the Pelvic lymph node coverage of conventional radiotherapy fields based on bone and vessels landmarks
using computed tomography (CT) simulation in patients with prostate cancer referred to Shohada-e-Tajrish hospital.
Patients and Methods: In this cross sectional study, 40 patients with prostate cancer at the Stage T1c to T3b were studied. Pelvic
lymph nodes were contoured by using pelvic vessels as surrogate markers. The distances were measured at different points of
anterior-posterior (AP) and lateral fields and distances > 5mmor more between the contoured nodes and the field borders.
Results: Meanand standard deviation of the aortic bifurcation from the superior border was 4.73+1.16 cm, the distance of common
iliac bifurcation from the superior border was 1.11 + 1.25 cm, the mean (SD) distance of right external iliac from the lateral border
of AP field was 2.06+0.48 cm and for left external iliac artery was 1.90+0.56 cm. The distance of the external iliac artery from the
anterior border of the lateral field was 2.30+0.74 cm. The distance of the external iliac artery from pelvic rim was 0.59+0.59 cm,
distance of bifurcation of iliac from sacroiliac joint was 0.82+1.01 cm, the size of the pelvic rim was 12.30+0.64 cm, sacral width
was 8.29 + 1.01 cm, anterior promontory symphysis distance was 12.02 + 0.92 cm and posterior promontory symphysis distance
was 10.98+0.73 cm.
Conclusions: We observed that conventional radiotherapy using CT simulation based on bone and vessels landmarks provided
adequate coverage of pelvic lymph nodes in our patients with prostate cancer.