Title of article
real-timeness improvement of can-based industrial networks based on criticality level
Author/Authors
ghodsollahee, ismail ferdowsi university of mashhad - dependable distributed embedded systems (ddems) laboratory, department of computer engineering, mashhad, iran , sedaghat, yasser ferdowsi university of mashhad - dependable distributed embedded systems (ddems) laboratory, department of computer engineering, mashhad, iran
From page
8
To page
17
Abstract
although applying new internet-based communication technologies on industrial physical processes made great improvements in factory automation, there are still many challenges to meet the response time and reliability requirements of industrial communications. these challenges resulted from strict real-time requirements of industrial control system communications which are performed in harsh environments. the controller area network (can) communication protocol is commonly employed to deal with these challenges. however, in this protocol, even message retransmission requests of a faulty node can lead to timing failures. in this paper, to control the behavior of nodes, message retransmission is performed based on the criticality level of message reception. the proposed method, called mrmc+, improves the real-time behavior of a can bus in terms of response time by an average of 36.32% and 18.02%, respectively, compared to the standard can and wcter-based approaches.
Keywords
controller area network , reliability , real , timeness , criticality level , consumed bandwidth reduction
Journal title
International Journal of Information and Communication Technology Research
Journal title
International Journal of Information and Communication Technology Research
Record number
2705202
Link To Document