• Title of article

    Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study

  • Author/Authors

    Matsutomo ، Norikazu Department of Medical Radiological Technology - Faculty of Health Sciences - Kyorin University , Hashimoto ، Takeyuki Department of Medical Radiological Technology - Faculty of Health Sciences - Kyorin University , Fukami ، Mistuha Department of Medical Radiological Technology - Faculty of Health Sciences - Kyorin University , Yamamoto ، Tomoaki Department of Medical Radiological Technology - Faculty of Health Sciences - Kyorin University

  • From page
    117
  • To page
    125
  • Abstract
    Objective(s): The purpose of this study was to validate undersampled single-photon emission computed tomography (SPECT) imaging using a combination of compressed sensing (CS) iterative reconstruction (CS-IR) and offset acquisition. Methods: Three types of numerical phantoms were used to evaluate image quality and quantification derived from CS with offset acquisition. SPECT images were reconstructed using filtered back-projection (FBP), maximum likelihood-expectation maximization (ML-EM), CS-IR, and CS-IR with offset acquisition. The efficacy of CS-IR with offset acquisition was examined in terms of spatial resolution, aspect ratio (ASR), activity concentration linearity, contrast, percent coefficient of variation (%CV), and specific binding ratio (SBR). Results: The full widths at half maximum remained unchanged as the number of projections decreased in CS-IR with offset acquisition. Changes in ASRs and linearities of count density were observed for ML-EM and CS-IR from undersampled projections. The %CV obtained by CS-IR with offset acquisition was substantially lower than that obtained by ML-EM and CS-IR. There were no significant differences between the %CVs obtained from 60 projections by CS-IR with offset acquisition and from 120 projections by FBP. Although the SBRs for CS-IR with offset acquisition tended to be slightly lower than for FBP, the SBRs for CS-IR with offset acquisition did not change with the number of projections. Conclusions: CS-IR with offset acquisition can provide good image quality and quantification compared with a commonly used SPECT reconstruction method, especially from undersampled projection data. Our proposed method could shorten overall SPECT acquisition times, which would benefit patients and enable quantification with dynamic SPECT acquisitions.
  • Keywords
    Compressed sensing , rapid acquisition , dynamic SPECT , dopamine transporter imaging , SPECT reconstruction
  • Journal title
    Asia Oceania Journal of Nuclear Medicine and Biology
  • Journal title
    Asia Oceania Journal of Nuclear Medicine and Biology
  • Record number

    2711501