Title of article :
Uncertainty Analysis of H_p(10)_meas/H_p(10)_del Ratio for TLD-100H at Energy 24-1250 keV
Author/Authors :
Priharti, W. Universiti Kebangsaan Malaysia - Faculty of Science and Technology, School of Applied Physics, Malaysia , Samat, S. B. Universiti Kebangsaan Malaysia - Faculty of Science and Technology, School of Applied Physics, Malaysia , Kadir, A. B. A. Universiti Kebangsaan Malaysia - Faculty of Science and Technology, School of Applied Physics, Malaysia
From page :
115
To page :
118
Abstract :
The H_p(10) of an ideal TLD is independent of photon energy. This is to say that at any photon energy, the ratio R of the measured dose H_p(10)_meas to the delivered dose H_p(10)_del is always 1. In practice however the H_p(10) is dependent on the energy and R is not equal to 1. For this reason, ICRP has set the lower limit LL and upper limit U_L for R as 0.55≤R≤1.63 for detection limit of 0.1 mSv and H_p(10)_del=1 mSv. As R is the quantity arises from the measurement processes, the existence of uncertainty of R, i.e. ΔR is inevitable. In the boundary cases, such as when R is slightly lower than L_L or slightly larger than U_L, ΔR would serve a useful quantity in decision making either to accept or to reject the value of R. The purpose of the present work is to estimate ΔR for the TLD- 100H for photon energy of 24-1250 keV. The estimation of ΔR is based on the error propagation method. For the eleven photon energies, this work obtained (a) R in the range of 0.77 to 1.16, (b) ΔR in the range of ± 0.02 to ± 0.04. The values of R were satisfactory as they complied the ICRP limit. The determined ΔR is considered very small as it is in the order of 3% in comparison of R.
Keywords :
Energy dependence , H_p(10) uncertainty , ICRP trumpet graph , TLD , 100H
Journal title :
Jurnal Teknologi :F
Journal title :
Jurnal Teknologi :F
Record number :
2716176
Link To Document :
بازگشت