Title of article :
Effect of Liquid Inhibitor De-dio^TM on Dioxin-Furan Emission from Medical Waste Incineration Plant
Author/Authors :
Rashid, M. Malaysia-Japan International Institute of Technology - Air Resources Research Laboratory, Malaysia , Ramli, M. Universiti Teknologi Malaysia - Faculty of Chemical Engineering, Malaysia , Ammar, M. AMR Environmental Sdn Bhd, Taman Sri Pulai Perdana, Malaysia , Noorhafizah, K. AMR Environmental Sdn Bhd, Taman Sri Pulai Perdana, Malaysia
From page :
47
To page :
51
Abstract :
The aim of the study was to investigate the effects of liquid inhibitor (known as De-dio^TM) on the emission of dioxin-furan from medical waste incineration plants. Various concentrations of De-dio^TM solutions were tested on the medical waste incinerator combustion chamber with an injection flow rate of 1.5 L/min. The sampling protocol of US EPA Method 23 was adopted to collect the sample using a modified US EPA Method 5 sampling train. The flue gas emission was collected before and during the injection of the chemical. The result showed that the De-dio^TM was able to reduce or minimize the formation of dioxinfuran to meet its regulatory limits. The study illustrates that the higher the concentration of De-dio^TM solution, the lower the dioxin-furan emission was observed in the flue gas.
Keywords :
Inhibitors , dioxin , furan , incineration , medical waste