• Title of article

    Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials

  • Author/Authors

    Farnoush, F Faculty of Dentistry - Islamic Azad University of Medical Sciences - Tehran, Iran , Ansari Lari, Homeira Prosthodontics Department - Membership of Dental Material Research Center - Faculty of Dentistry - Islamic Azad University of Medical Sciences - Tehran, Iran , Fatemi, Seyed Mostafa Department of Dental Materials - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran

  • Pages
    8
  • From page
    14
  • To page
    21
  • Abstract
    Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability. Materials and Methods: In this in-vitro experimental study, dimensional changes of two types of alginate were investigated indirectly by measuring a type III stone cast. Ninety molds of each alginate were obtained from a metal model and stored at 1±4, 1±25, and 1±40°C. The casting was performed 12 minutes, 1 hour, and 4 hours after impression taking. The molds were incubated with an approximate humidity of 100%. The diameter, width, and height of the gypsum casts were measured by a digital caliper with an accuracy of 0.01 mm. Dimensional changes of two alginates in three separate directions were statistically analyzed by three-way analysis of variance (ANOVA) and post-hoc test due to the significant difference. Result: There was no statistically significant difference in width changes at different temperatures, but regarding the diameter, there was a significant difference between 40°C Chromogel and 25°C Hygedent. Regarding the height, only 40°C Hygedent showed a significant difference at 4 hours compared to 12 minutes (P=0.000, 0.26, and 0.000, respectively). However, no statistically significant difference was observed in other temperatures and times (P>0.05). In most groups, dimensional changes of all samples were not within the clinical standard range (1%). Conclusion: It seems that the dimensional stability of Hygedent and Chromogel alginates is affected by storage temperature, pouring time, and type of alginate.
  • Keywords
    Dimensional Stability , Temperature , Time , Alginate
  • Journal title
    Journal of Research in Dental and Maxillofacial Sciences
  • Serial Year
    2021
  • Record number

    2717743