Title of article
Performance study of a supersonic inlet in the presence of a heat source
Author/Authors
Soltani, M. R. sharif university of technology - Department of Aerospace Engineering, تهران, ايران , Farahani, M. sharif university of technology - Department of Aerospace Engineering, تهران, ايران , Sepahi Younsi, J. sharif university of technology - Department of Aerospace Engineering, تهران, ايران
From page
375
To page
382
Abstract
The flow over a supersonic inlet has been investigated experimentally and numerically at a free stream Mach number of 2 and a zero degree angle of attack. Wind tunnel tests were performed to obtain the performance parameters of the inlet and were used as a baseline and validation tools for the numerical code. A heat source was added to the flow field at a distance ahead of the inlet. The effect of heat source addition on the main performance parameters of the inlet is investigated numerically. Results show that the heat source considerably reduces drag coefficient; however, its effect on pressure recovery is not favorable. This unfavorable effect was then minimized by controlling heat source parameters, such as its location, size and shape. For the optimum condition, drag coefficient reduces considerably, inlet mass flow rate increases, but pressure recovery slightly decreases.
Keywords
Supersonic inlet , Heat source , Drag coefficient , Pressure recovery , Mass flow rate.
Journal title
Scientia Iranica(Transactions B:Mechanical Engineering)
Journal title
Scientia Iranica(Transactions B:Mechanical Engineering)
Record number
2718249
Link To Document