• Title of article

    Microbial Air Monitoring in the Pediatric Burn Ward: Experience at the University Hospital of Mashhad, Iran

  • Author/Authors

    Rahnama Bargard, Zohreh Student Research Committee - Mashhad University of Medical Sciences, Mashhad - Iran an‎d MSc of Environmental Health Engineering - Department of Environmental Health Engineering - School of Health - Mashhad University of Medical Sciences, Mashhad, Iran , Najafpoor, Ali Asghar Department of Environmental Health Engineering - School of Health - Mashhad University of Medical Sciences, Mashhad, Iran , Alidadi, Hoseein Department of Environmental Health Engineering - School of Health - Mashhad University of Medical Sciences, Mashhad, Iran , Pazira, Muhammad Student Research Committee - Mashhad University of Medical Sciences, Mashhad - Iran an‎d MSc of Environmental Health Engineering - Department of Environmental Health Engineering - School of Health - Mashhad University of Medical Sciences, Mashhad, Iran , Ejtehadi, Mohamad Mahdi Ph D Laboratory Sciences - Mashhad University of Medical Sciences, Mashhad, Iran , Ghavami, Vahid Department of Epidemiology & Biostatistics - School of Health - Mashhad University of Medical Sciences, Mashhad, Iran , Sarkhosh, Maryam Department of Environmental Health Engineering - School of Health - Mashhad University of Medical Sciences, Mashhad, Iran

  • Pages
    15
  • From page
    14061
  • To page
    14075
  • Abstract
    Background The aim of this study was to investigate the density and type of bacterial and fungal bioaerosols in the air of the pediatric burn ward. Materials and Methods In this cross-sectional study, two active and passive sampling methods were used simultaneously to evaluate the density and type of bacterial and fungal bioaerosols. In 2019, sampling was performed once every six days, according to the sampling guideline developed by the 2019 United States Environmental Protection Agency (EPA). Data were analyzed using SPSS software (version 22.0). Results According to the EU GMP standard, in the active method, bacterial and fungal contaminations in the indoor air of the burn ward were in grades C and D, respectively. According to this standard, in the active method, bacterial and fungal contaminations in the outdoor air of the burn ward were in grade C. According to the EU GMP standard, in the passive method, bacterial and fungal contaminations in the indoor air of the pediatric burn ward were in grade C. According to this standard, in the passive method, bacterial and fungal contaminations in the outdoor air of the burn ward were in grade C. Conclusion Given the importance of preventing infection in patients with burns and preventing deaths caused by infections in these patients, especially in children with burns, it is necessary to pay attention to the role of bioaerosols in developing nosocomial infections in burn patients.
  • Keywords
    Bioaerosol , Bacterial , Burn , Fungal
  • Journal title
    International Journal of Pediatrics
  • Serial Year
    2021
  • Record number

    2727231