Title of article :
Screening Performance Characteristics of Ultrasonography in Confirmation of Endotracheal Intubation; a Systematic Review and Meta-analysis
Author/Authors :
Farrokhi, Mehrdad Eris Research Institute, Tehran, Iran , Yarmohammadi, Bardia School of Medicine - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Mangouri, Amir Department of Vascular and Endovascular Surgery - Sina Hospital - Tehran University of Medical Sciences, Tehran, Iran , Hekmatnia, Yasaman Islamic Azad University Sari Branch, School of Medicine, Sari, Iran , Bahramvand, Yaser School of Medicine - Shiraz University of Medical Sciences, Shiraz, Iran , Kiani, Moein School of Medicine - Zanjan University of Medical Sciences, Zanjan, Iran , Nasrollahi, Elham School of Medicine - Shiraz University of Medical Sciences, Shiraz, Iran , Nazari-Sabet, Milad Department of General Surgery - School of Medicine - Isfahan University of Medical Sciences, Isfahan, Iran , Manoochehri-Arash, Niusha Endocrine Research Center, Research Institute for Endocrine Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Khurshid, Maria Department of Internal Medicine - Berkshire Medical Center, Massachusetts, USA , Mosalanejad, Shima Department of Internal Medicine - Faculty of Medicine - Islamic Azad University Tehran Medical Sciences Branch, Tehran, Iran , Hajizadeh, Vida School of Dentistry - Shiraz University of Medical Sciences, Shiraz, Iran , Amani-Beni, Reza School of Medicine - Isfahan University of Medical Sciences, Isfahan, Iran , Moallem, Masoumeh Department of Emergency Medicine - School of Medicine - Islamic Azad University Tehran Medical Sciences Branch, Tehran, Iran , Farahmandsadr, Maryam School of Medicine - Jahrom University of Medical Sciences, Jahrom, Iran
Pages :
17
From page :
1
To page :
17
Abstract :
Introduction: Recent studies have suggested that point-of-care ultrasonography can be used for confirming the placement of endotracheal tube. This systematic review and meta-analysis aimed to investigate the sensitivity and specificity of ultrasonography for confirming endotracheal tube placement. Methods: In thismeta-analysis, systematic search of the previous published papers investigating the diagnostic accuracy of ultrasonography for confirmation of endotracheal tube placement was performed. Seven electronic databases, including PubMed, Scopus, Google Scholar, EBSCO, EMBASE, Web of Science, and Cochrane Database were searched up to July 2021, for all relevant articles published in English on this topic. Meta-DiSc version 1.4 software was used for statistical analysis. Results: The estimated pooled sensitivity and specificity of ultrasonography for confirmation of endotracheal tube location were 0.98 (95% CI: 0.98–0.99) and 0.94 (95% CI 0.91–0.96), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 5.94 (95% CI 4.41–7.98) and 0.03 (95% CI: 0.02-0.04), respectively. The diagnostic odds ratio of ultrasonography was 281.47 and the area under hierarchical summary receiver operating characteristic (HSROC) revealed an appropriate accuracy of 0.98. Conclusion: Ultrasonography has high diagnostic accuracy and can be used as a promising tool for confirmation of endotracheal tube placement, especially in critically ill patients or when capnography is not available, or its result is equivocal.
Keywords :
Airway management , intubation , meta-analysis , sensitivity and specificity , ultrasonography
Journal title :
Archives of Academic Emergency Medicine (AAEM)
Serial Year :
2021
Record number :
2730338
Link To Document :
بازگشت