Rasalkar ، Pavan Department of Cardiology - Postgraduate Institute of Medical Education and Research , Vemuri ، Krishna santosh Departement of Cardiology - Institute of Medical Sciences - Banaras Hindu University , Bootla ، Dinakar Department of Cardiology - Postgraduate Institute of Medical Education and Research , Revaiah ، Pruthvi C Department of Cardiology - Postgraduate Institute of Medical Education and Research , Mishra ، Anand Kumar Department of Cardiothoracic Surgery - Postgraduate Institute of Medical Education and Research , Dahiya ، Neelam Department of Cardiology - Postgraduate Institute of Medical Education and Research , Ghosh ، Soumitra Department of Cardiology - Postgraduate Institute of Medical Education and Research , Barwad ، Parag Department of Cardiology - Postgraduate Institute of Medical Education and Research
From page
147
To page
151
Abstract
Inadvertent deployment of stent grafts into the false lumen during thoracic endovascular aortic repair (TEVAR) is rare and is associated with catastrophic consequences. We present a case of accidental stent-graft deployment from the true lumen into the false lumen during TEVAR, resulting in hemodynamic collapse and visceral malperfusion. We successfully performed a bailout using the Brockenbrough needle to create new access from the true lumen to the false lumen and implanted another overlapping stent graft.
Keywords
Thoracic endovascular aortic repair (TEVAR) , False lumen implantation , Brockenbrough needle , Endovascular rescue
Journal title
The Journal of Tehran University Heart Center (JTHC)
Journal title
The Journal of Tehran University Heart Center (JTHC)
Record number
2750174
Link To Document