Title of article :
Thermo-Hydraulic Performance of Tube Type Heat Exchanger with Semi-Circular Cut Twisted Tape Insert: A Numerical Exploration
Author/Authors :
Diwaker ، Manoj Kumar Department of Mechanical Engineering - Maulana Azad National Institute of Technology (MANIT) Bhopal , Kumar ، Arvind Department of Mechanical Engineering - Maulana Azad National Institute of Technology (MANIT) Bhopal
From page :
159
To page :
170
Abstract :
The present study aimed to investigate the effects of the semi-circular cut twisted tape insert in tube type heat exchangers. The study selected twist ratios of 4.5, 5.5, and 6.5mm, and cut diameters of 5mm, 8mm, and 11mm. The Reynolds number ranged from 4000-16000. The study quantitatively demonstrated the impacts of cut diameter and twist ratio in terms of Nusselt number, friction factor, and thermal performance factor. The aforementioned output parameters were employed as metrics to assess the efficacy of the twisted tape insert. The obtained results reveal that smaller twist generates extra swirl which intensifies heat transfer. Also, as the diameter of the cut increases Nusselt number increases. In a quantitative analysis, it was observed that when Re=4000, the plain twisted tapes with y=4.5, 5.5, and 6.5 exhibited maximum thermal performance factors of 1.36, 1.32, and 1.21, respectively. On the other hand, for the modified twisted tapes (having a cut diameter of 11mm), the values were higher, measuring 1.84, 1.77, and 1.68 for the same respective ‘y’ values.
Keywords :
Tube type heat exchanger , Convective heat transfer , Heat transfer coefficient , Friction Factor , Nusselt Number
Journal title :
Journal of Heat and Mass Transfer Research
Journal title :
Journal of Heat and Mass Transfer Research
Record number :
2754839
Link To Document :
بازگشت