Title of article
Performance of different Strength of Aperture Shape Controller on VMAT technique for Head and Neck, Pelvis, and Breast Cancer using Halcyon Machine
Author/Authors
Erraoudi ، Morad Faculty of Sciences - Mohammed V University , Bouzekraoui ، Youssef Laboratory of Sciences and Health Technologies - High Institute of Health Sciences - Hassan First University of Settat , Herrassi ، Mohammed Yassine Private Hospital Casablanca-AKDITAL , Elouardi ، Khalid Department of physics - University of Mohammed 1st , Raoui ، Yassir Faculty of Sciences - Mohammed V University , El ghalmi ، Mohamed Faculty of Sciences - Mohammed V University , BENTAYEB ، FARIDA Laboratory of High Energy Physics - Faculty of Science - Mohammed V Agdal University
From page
168
To page
175
Abstract
Introduction: Before starting optimization using the Volumetric Modulated Arc Therapy (VMAT) technique, the choice of the convenient aperture shape controller can be one of the most important factors that affect the plan quality.Material and Methods: Three different clinical cases were selected: head and neck cancer, pelvic cancer (prostate, cervix, and endometrium), and breast cancer treated with the VMAT technique. By keeping the same conditions, plans were reoptimized by varying aperture shape controllers (OFF, VERY LOW, LOW, MODERATE, HIGH, VERY HIGH). For plans evaluation, the homogeneity index (HI), conformity index (CI), target coverage (D98% and V98%), dose max (DMAX) and near max (D2%), treatment time delivery (MUs), and gamma index passing rate were analyzed.Results: All the studied localizations treated with the VMAT technique met clinical objectives. The VERY LOW technique achieved the best dose conformity for all localizations. A slight improvement in terms of PTV coverage and max dose is obtained in a VERY LOW technique for pelvic cancer. For breast cancer, almost the same results were obtained. However, for head and neck treatments, better results were observed with the HIGH and VERY HIGH techniques, where coverage and maximum dose improved by up to 6%.Conclusion: Changing the Strength of Aperture Shape Controller in VMAT optimization can affect dose calculation, especially in concave volumes such as Head and Neck.
Keywords
Target Coverage , Leaf Sequencing , Cancer , Beamlets , VMAT technique , Aperture Shape Controller , optimization
Journal title
Iranian Journal of Medical Physics (IJMP)
Journal title
Iranian Journal of Medical Physics (IJMP)
Record number
2760485
Link To Document