Title of article
Feasibility of direct brain 18F-fluorodeoxyglucose-positron emission tomography attenuation and high-resolution correction methods using deep learning
Author/Authors
Ueda ، Tomohiro Graduate School of Health Sciences - Kumamoto University , Yamshita ، Kousuke Graduate School of Health Sciences - Kumamoto University , Kawazoe ، Retsu Graduate School of Health Sciences - Kumamoto University , Sayawaki ، Yuta Graduate School of Health Sciences - Kumamoto University , Morisawa ، Yoshiki Graduate School of Health Sciences - Kumamoto University , Kamezaki ، Ryosuke Kumamoto University Hospital , Ikeda ، Ryuji Department of Central Radiology - Kumamoto University Hospital , Shiraishi ، Shinya Department of Diagnostic Radiology - Faculty of Life Sciences - Kumamoto University , Uchiyama ، Yoshikazu Department of Information and Communication Technology - Faculty of Engineering - University of Miyazaki , Ito ، Shigeki Department of Medical Radiation Sciences - Faculty of Life Sciences - Kumamoto University
From page
108
To page
119
Abstract
Objective(s): To develop the following three attenuation correction (AC) methods for brain 18F-fluorodeoxyglucose-positron emission tomography (PET), using deep learning, and to ascertain their precision levels: (i) indirect method; (ii) direct method; and (iii) direct and high-resolution correction (direct+HRC) method.Methods: We included 53 patients who underwent cranial magnetic resonance imaging (MRI) and computed tomography (CT) and 27 patients who underwent cranial MRI, CT, and PET. After fusion of the magnetic resonance, CT, and PET images, resampling was performed to standardize the field of view and matrix size and prepare the data set. In the indirect method, synthetic CT (SCT) images were generated, whereas in the direct and direct+HRC methods, a U-net structure was used to generate AC images. In the indirect method, attenuation correction was performed using SCT images generated from MRI findings using U-net instead of CT images. In the direct and direct+HRC methods, AC images were generated directly from non-AC images using U-net, followed by image evaluation. The precision levels of AC images generated using the indirect and direct methods were compared based on the normalized mean squared error (NMSE) and structural similarity (SSIM).Results: Visual inspection revealed no difference between the AC images prepared using CT-based attenuation correction and those prepared using the three methods. The NMSE increased in the order indirect, direct, and direct+HRC methods, with values of 0.281×10-3, 4.62×10-3, and 12.7×10-3, respectively. Moreover, the SSIM of the direct+HRC method was 0.975.Conclusion: The direct+HRC method enables accurate attenuation without CT exposure and high-resolution correction without dedicated correction programs.
Keywords
Brain PET , Attenuation Correction , high , resolution correction , DCNN
Journal title
Asia Oceania Journal of Nuclear Medicine and Biology
Journal title
Asia Oceania Journal of Nuclear Medicine and Biology
Record number
2763977
Link To Document