• Title of article

    Comparing the Curing Quality of Bulk-fill and Conventional Composites at Various Irradiation Times and Depths

  • Author/Authors

    Elmamooz ، Nafiseh Department of Operative Dentistry - School of Dentistry - Kerman University of Medical Sciences , Rezaei ، Mehdi Department of Operative Dentistry - School of Dentistry - Kerman University of Medical Sciences , Eskandarizade ، Ali Department of Operative Dentistry - School of Dentistry - Kerman University of Medical Sciences , Bagherinasab ، Maryam , Karimi Afshar ، Mehrnaz Department of Prosthodontics - School of Dentistry - Shiraz University of Medical Sciences

  • From page
    174
  • To page
    179
  • Abstract
    Background: Bulk-fill composites are a new class of materials introduced to speed up the clinical process of posterior restorations. This study compared the curing quality of bulk-fill and conventional composites at different irradiation times and depths.Methods: In this in-vitro study, 40 specimens from a bulk-fill composite, Tetric N-Ceram bulk-fill (TNB), and a conventional composite, Tetric N-Ceram (TN), were fabricated using a metal mold (6 mm × 4 mm) (n = 10). The composites were placed and cured in bulk for each composite. For each composite, half of the samples were cured for 20 seconds (s) using a light-emitting diode (LED) curing unit, and the irradiation time for the other half was 40. After 24 hours of storage in distilled water, the hardness of the samples was measured using a microhardness tester at different depths (0.1, 1, 2, 3, and 4 mm). Statistical analysis was done using multivariate ANOVA and independent t test (P ˂ 0.05).Results: Both composites presented a significant reduction in hardness value with increasing depth. TNB showed significantly higher hardness values at all depths in both irradiation times than conventional composite. TNB composite did not achieve a depth of cure (DOC) of 4 mm at any of the two curing times. Irradiation time significantly affects hardness values in both composites.Conclusion: Given that neither bulk-fill nor conventional composite was cured at depths greater than 3 mm, it is suggested that prolonged curing cycles be used to improve the DOC of composites.
  • Keywords
    Composite , bulk fill , Hardness , irradiation time , depth of cure
  • Journal title
    Journal of Kerman University of Medical Sciences (JKMU)
  • Journal title
    Journal of Kerman University of Medical Sciences (JKMU)
  • Record number

    2771052