Title of article :
Chronic Dose Due to a Continuous Tritium Release Calculated by CAP88-PC and NORMTRI
Author/Authors :
Overcamp، Thomas J. نويسنده , , Imboden، Stacey F. نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
-113
From page :
114
To page :
0
Abstract :
CAP88-PC, Version 2.0, and NORMTRI, which are based on the Gaussian plume model, were used to estimate the chronic dose due to a continuous, ground-level, atmospheric release of tritium as tritiated water. For the same conditions the predictions of CAP88-PC were found to be higher by a factor of 3 or less than those of NORMTRI. The major differences are due to the use of higher dose coefficients in CAP88-PC and NORMTRIʹs method of calculating the tritium content of food.