Title of article :
Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing
Author/Authors :
Chen، Chao-Ru نويسنده , , Sun، Feng-ling نويسنده , , Feng، Lei نويسنده , , Liu، Ming نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
-330
From page :
331
To page :
0
Abstract :
In this paper, we report on an underground water-source water-loop heat-pump (UWSWLHP) air-conditioning system for a tall apartment building in Beijing. Water at 14 °C was used as an external low-temperature heat-source. By analyzing field-test data for two years, the authors assessed the operating and controlling conditions of the system. Based on the electricity consumed by public-use airconditioning power equipment and terminal heat-pumps, the authors put forward an overall evaluation of the energy-conservation characteristics of the system.
Keywords :
Field-test data , Analysis of energy consumption , Residential building , Underground water source , Water-loop heat pump air-conditioning system