• Title of article

    TEMPERATURE DISTRIBUTION AT THE MEMBRANE WALL OF A 165-MWth CFB BOILER

  • Author/Authors

    Golriz، Mohammad R. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    -298
  • From page
    299
  • To page
    0
  • Abstract
    The temperature distribution was investigated in the combustor of a 165-MWth, atmosphericpressure circulating fluidized-bed (CFB) boiler located in ?rebro, Sweden. The temperature was measured with a bare 1-mm Chromel-Alumel thermocouple at different heights and at different distances from the fin surface of the membrane wall. The investigation covers two fuels (coal and peat) at boiler loads of 85 and 165 MWth, respectively. The results show that the thermal boundary-layer thickness increases with increasing height and with decreasing superficial gas velocity. The fuel has a significant influence in the lower and upper parts of the combustion chamber. In addition, the results from this boiler are compared with other available temperature distribution data in the literature.
  • Keywords
    post-tensioned concrete , radial reinforcement , iteration , cracking , Delamination , hoop bending moment , hoop tension , reinforced con-crete
  • Journal title
    EXPERIMENTAL HEAT TRANSFER
  • Serial Year
    2001
  • Journal title
    EXPERIMENTAL HEAT TRANSFER
  • Record number

    38498