Title of article
An Automatic Nonrigid Registration for Stained Histological Sections
Author/Authors
M. Auer، نويسنده , , P. Regitnig ، نويسنده , , G. A. Holzapfel ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
12
From page
475
To page
486
Abstract
Automatic computer-based analyses of histological
sections which are differently stained require that they are related
to each other. Most registration methods are only able to perform
rigid-body motion and are sensitive to noise and artifacts. Histological
images, however, are accompanied by several artifacts and
different contrasts, which require a nonrigid registration. In this
paper, we present a hierarchical nonrigid registration algorithm
able to align images, which contain minor image artifacts. The
algorithm requires no a priori knowledge of the true image. The
hierarchical design of the algorithm enhances robustness and accuracy,
and saves computational costs. The proposed algorithm is
decomposed into a fast, coarse, rigid registration step and a slower,
but finer, nonrigid step. For the coarse registration, we use image
pyramids, while for the second step, we combine a point-based
registration with an elastic thin-plate spline interpolation. Accuracy
tests, performed for 20 histological images obtained from
human arteries, have shown that the error measure is acceptable,
and that the image noise does not cause a problem. The associated
convergence rate of the mean pixel displacement error during the
rigid and nonrigid registrations is satisfying. The algorithm can
be applied to various multicontrast elastic registration problems
in medical imaging and may be extended to three dimensions.
Keywords
similaritymeasure , thin-plate spline (TPS) interpolation. , histologicalimage , Atherosclerotic human arteries , Image pyramid , nonrigid registration method