A high-volume slit nozzle virtual impactor has been developed to collect fine and coarse particles. The size cut-off and particle loss characteristics of the developed slit virtual impactor agree well with those of the 16.7lmin^-1 commercially available dichotomous sampler. The effects of various flow and physical design parameters on the collection of both fine and coarse particles have been investigated. The results of these tests indicated that many of the theoretical principles established for round nozzle virtual impactors can be successfully applied to slit nozzle virtual impactors. However, the effects of the flow volume and Reynolds number (Re) on the cut-off behavior and particle losses are more pronounced for slit virtual impactors. The impactorʹs particle size cutpoint decreased as the total inlet flow and Re increased. For Re
7000, losses of fine particles were significant, while coarse particle losses were low. Changes in the minor-to-total flow ratio and collection slit width also affected particle losses.