Title of article
A new time domain voltage source model for an arc furnace using EMTP
Author/Authors
Varadan، نويسنده , , S.، نويسنده , , Makram، نويسنده , , E.B.، نويسنده , , Girgis، نويسنده , , A.A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
7
From page
1685
To page
1691
Abstract
This paper presents a new time domain
Controlled Voltage Source (CVS) model for an arc furnace
using the Electro Magnetic Transients Program (EMTP). The
developed model is based on a piece wise linear approximation
of the v-i characteristic of the arc furnace load. In addition to
this, the novelty of this simulation technique lies in the fact
that the active power consumed by the load is also considered
in the proposed load model, thus making the proposed load
model dependent on the operating conditions of the load.
Dynamic variation of the arc is incorporated through
sinusoidal and band limited white noise variation of the arc
resistance in the v-i characteristic of the arc furnace load.
Depending on the variation of the arc resistance, the developed
load model accurately represents both static (deterministic)
and dynamic (random) arc characteristics. While static arc
models are useful for harmonic studies, dynamic models are
useful for power quality studies and in particular, the study of
voltage flicker. The results are compared with actual voltage
measurements taken from a local utility to prove the validity of
the proposed load model.
Keywords
Load model , EMTP , arc furnace , Harmonics , Voltage flicker
Journal title
IEEE TRANSACTIONS ON POWER DELIVERY
Serial Year
1996
Journal title
IEEE TRANSACTIONS ON POWER DELIVERY
Record number
399241