Title of article :
Frequency relaying based on instantaneous frequency measurement [power systems]
Author/Authors :
Moore، نويسنده , , P.J.، نويسنده , , Allmeling، نويسنده , , J.H.، نويسنده , , Johns، نويسنده , , A.T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
6
From page :
1737
To page :
1742
Abstract :
A frequency relay capable of underlover frequency and rate of change of frequency measurements has been implemented on a digital signal processor using an instantaneous frequency measuring algorithm. Careful attention to the filtering aspects of the relay is needed under dynamic conditions due to frequency modulation of the input signal. An algorithm for avoiding unwanted relay operation due to impulsive changes in the input signal is presented. Results are shown for simulated tests using computer based relay testing equipment, and for overloads on a micromachine power system simulator.
Keywords :
Frequency measurement , frequency relaying , digital signal processing