A termination for 77kV-class high Tc
superconducting power cables was designed and fabricated.
The termination is insulated with SF6 gas, nitrogen gas and
liquid nitrogen and is cooled withi liquid nitrogen. The current
lead has a cross sectional area altered along its axis in order to
decrease the heat inlet and to prevent SF6 gas from liquefying.
The current lead is insulated with Ethylene-propylene Rubber
(EPR) because it passes through nitrogen gas which has low
dielectric strength in comparison with liquid nitrogen and SF6
gas. 200A AC current and 70kV AC voltage to ground were
successfully applied simultaneously for 40 hours in total. The
measured heat loss of the termhation, 19W, is in good
agreement with the calculated value. As the next step, the
applied voltage was increased and the termination was
confirmed to withstand the voltage up to 12OkV AC and 4OOkV
Imp to ground.