Title of article :
Behaviour of the DC leakage currents of polymeric metal oxide surge arresters in water penetration tests
Author/Authors :
Lahti، نويسنده , , K.، نويسنده , , Kannus، نويسنده , , K.، نويسنده , , Nousiainen، نويسنده , , K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
6
From page :
459
To page :
464
Abstract :
The behaviour of seven commercially available polymer housed metal oxide surge arrester types was studied in +7OoC and boiling water immersion tests. DC leakage current of the arresters was used to diagnose the humidity penetration inside an arrester. The recovery features after an immersion test for different arrester types were measured and discussed. Together with the immersion and recovery tests a humidity penetration test in very humid air was performed. For the first time the behaviour of different arrester types in immersion tests was compared to their behaviour in a humidity penetration test with realistic ambient conditions. The resistance to moisture penetration varied greatly in the arrester types tested. Also recovery of the DC leakage current varied between the arrester types depending on their structure. The results from the tests in very humid air indicated similar arrester behaviours than the results from the other tests and suggest ideas for diagnosing arrester behaviour.
Keywords :
Polymeric metal oxide surge arresters , tightness testing , DC leakage current diagnostics
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Serial Year :
1998
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Record number :
399570