Title of article :
Electromagnetic compatibility of high voltage transmission lines and the guidance of center pivot irrigation units with cornering systems
Author/Authors :
Olsen، نويسنده , , R.G.، نويسنده , , Heins، نويسنده , , G.L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Abstract :
A study was done to determine if electromagnetic
fields of high voltage transmission lines can interfere with
electromagnetically guided cornering systems associated with
some center pivot irrigation units. Using electromagnetic
susceptibility tests, it was found that 60 hertz magnetic fields
of more than approximately 500 mG (milligauss) are required
to cause interference with the operation of one system. This
level is significantly higher than those found near most high
voltage transmission lines. It was also found that the
magnetic fields at harmonic frequencies and wideband fields
due to corona on the transmission line studied were
insufficient to cause interference with cornering guidance
systems. Observations of center pivot cornering systems
operating properly near 345 kV transmission lines in
Nebraska confirmed these results.
Keywords :
Electromagnetic CompatibilityTransmission Lines , High VoltageSystems , Irrigation
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY