• Title of article

    Dielectric breakdown strength correlation with time-to-failure during wet aging of XLPE-insulated cables

  • Author/Authors

    Walton، نويسنده , , M.D.، نويسنده , , Bernstein، نويسنده , , B.S.، نويسنده , , Thue، نويسنده , , W.A.، نويسنده , , Smith، نويسنده , , J.T.، نويسنده , , III، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    6
  • From page
    750
  • To page
    755
  • Abstract
    This paper reviews two sets of failure information, the GMTF (a parameter obtained from time-to-failure results) and GMBD stress (a parameter that is calculated from AC breakdown test results), and suggests a correlation. The test results were obtained from accelerated aging experiments on full-sized medium voltage cables in carefully controlled and monitored water-filled tanks. Results show that the ambient temperature AC breakdown strength for equivalently aged cables is influenced primarily by voltage stress during aging-not by the aging temperature. The AC breakdown strength on equivalently aged cables was also shown to decrease with reductions in the aging voltage at all aging temperatures
  • Journal title
    IEEE TRANSACTIONS ON POWER DELIVERY
  • Serial Year
    1999
  • Journal title
    IEEE TRANSACTIONS ON POWER DELIVERY
  • Record number

    399823