Title of article :
Self-damping measurements of conductors with circular and trapezoidal wires
Author/Authors :
K. MUNASWAMY، نويسنده , , K.، نويسنده , , Haldar، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
Self-damping characteristics of three types of conductors
with seven different sizes were studied. Conductor types
considered were ACSR round and trapezoidal (TW) wires as well
as Self-damping (SD). The power method was used in the measurement
of self-damping of all three types of conductors. For each conductor,
damping measurements were made at three tension levels
(10, 25 and 40% of rated tensile strength of conductor) for frequencies
ranging from 5 to 55 Hz and normalized peak-to-peak amplitudes
varying between 25=f to 150=f where f is frequency in Hz.
Empirical relationships were derived to estimate the power dissipation
values for all other frequency and amplitude levels. Results obtained
from tests conducted on ACSR round and trapezoidal wire
conductors of similar diameter indicated that the ACSR TW conductor
in general has higher internal damping when compared to
ACSR round wire conductor. However this trend was not necessarily
observed at low frequencies. It was also noted that power
dissipation increases with increase in size of the conductor.
Keywords :
ACSR , self-damping measurements. , Compact conductor , trapezoidal
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY