Title of article
Statistical summation of the harmonic currents produced by a large number of single phase variable speed air conditioners: a study of three specific designs
Author/Authors
Gorgette، نويسنده , , F.A.، نويسنده , , Lachaume، R. نويسنده , , J.، نويسنده , , Grady، نويسنده , , W.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
7
From page
953
To page
959
Abstract
The Variable Speed Air Conditioner (VSAC) is a
large domestic distorting load.We investigate the impact of a large
number of VSAC’s on domestic harmonic levels.We present
• a general method to build a harmonic numerical model of a
passive filtered rectifier supplied by a distorted voltage,
• a statistical method to assess the total harmonic currents produced
by a large number of units running at various power
levels and supplied by various distorted voltages.
These two methods are applied to a rectifier used by many
VSACS. We also present results for two other rectifiers.
Keywords
VSAC. , single phase air conditioner , Diversity , analytical model , harmonic cancellation
Journal title
IEEE TRANSACTIONS ON POWER DELIVERY
Serial Year
2000
Journal title
IEEE TRANSACTIONS ON POWER DELIVERY