Title of article
Numerical electromagnetic field analysis of lightning current in tall structures
Author/Authors
Baba، نويسنده , , Y.، نويسنده , , Ishii، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
5
From page
324
To page
328
Abstract
The Numerical Electromagnetic Code (NEC-2) is
applied to the electromagnetic analysis of tall structures hit by
lightning. The advantage of the analysis using NEC-2 is that it can
accurately compute the current distribution along a conductor
system by the method of moments. The waveforms of the lightning
currents measured on freestanding tall structures are well
reproduced, and the computed waveforms of the electric and the
magnetic fields at some distance from the structure hit by lightning
agree fairly well with the measured waveforms. In the analysis,
a lightning channel is represented by a vertical conductor that is
loaded by series inductance and resistance so as to simulate the
slow propagation velocity of a current wave on the lossy channel.
This representation is demonstrated to be quite effective.
Keywords
lightning current , EMP , Numerical electromagneticfield analysis , tall structures.