Title of article :
Condition assessment of power transformer on-load tap-changers using wavelet analysis
Author/Authors :
Pengju Kang، نويسنده , , Birtwhistle، نويسنده , , D.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The operation of a power transformer On-Load
Tap-Changer (OLTC) produces a well-defined series of vibration
bursts as its signature. Due to the harmonic and nonstationary
nature of the transient vibration signal, traditional frequency and
time-frequency techniques are on longer effective for characterization
of this type of vibration signals, as the localized time domain
features, such as delays between bursts, the number of bursts, and
the strengths of bursts, are essential for the condition assessment
of OLTC. A wavelet transform based technique is developed in this
paper to characterize the OLTC vibration signals. This technique
gives a simplified format for displaying and representing the
essential features of the OLTC vibration signatures. Application
results from a selector type OLTC demonstrate that the features
extracted in the wavelet domain can be utilized to provide reliable
indications of the actual heath of an OLTC.