Title of article
Attenuation characteristics of high rate home-networking PLC signals
Author/Authors
Kim، نويسنده , , C.J.، نويسنده , , A. Raouf Chouikha، نويسنده , , M.F.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
6
From page
945
To page
950
Abstract
This paper reports an experimental investigation of
the influence of the high-frequency (HF) signal attenuation on the
load in residences and offices. A laboratory test and actual measurements
were performed in a residence and an office. The experiments
show that the attenuation characteristics are more dependent
on the number of loads than the type of loads connected.
In addition, the concentration of loads was found to determine
where the maximum attenuation of the HF signals would occur.
The types and the size of the loads, however, did not affect the attenuation
characteristics of the HF signals. Therefore, for a successful
high-rate power line carrier (PLC) home networking, the analysis
on the placement of the loads may have to be considered for better
understanding of signal attenuation for PLC modems and other
PLC-to-media adapters.
Keywords
home networking , power line carrier , PLC modem , signal attenuation.
Journal title
IEEE TRANSACTIONS ON POWER DELIVERY
Serial Year
2002
Journal title
IEEE TRANSACTIONS ON POWER DELIVERY
Record number
400428
Link To Document