Title of article
Impedance Measurement for Improved Power Quality—Part 2: A New Technique for Stand-Alone Active Shunt Filter Control
Author/Authors
M. Sumner، نويسنده , , B. Palethorpe، نويسنده , , D. W. P. Thomas، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
7
From page
1457
To page
1463
Abstract
Thiswork describes the development of a new “standalone”
active shunt filter. The control employs online power system
impedance measurement to optimize the current control algorithm
and to provide the filter’s reference currents. The current control
employs additional rotating frames of reference at fifth and
seventh harmonic frequencies and is specifically for high kilovoltampere
applications where the switching frequency is constrained
to 4 kHz. This results in an improved immunity to disturbances
such as supply distortion, pulse-width modulation (PWM) imperfections
and processing delays, and provides excellent steady-state
current control. Experimental results confirm the operation of the
new controller.
Keywords
Impedance measurement , power quality , powersystem harmonics.