Title of article :
Electric Field Analysis of Water Drop Corona
Author/Authors :
Z. Guan، نويسنده , , L. Wang، نويسنده , , B. Yang، نويسنده , , X. Liang، نويسنده , , and Z. Li، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
964
To page :
969
Abstract :
Water drops on surface of polymer insulation materials may cause corona because they can enhance the electric field nearby. Water drop corona plays an important negative role in the long-term performance of composite insulators. In this paper, based on a model with two parallel electrodes water drop corona is studied. The relationship between initial corona voltage and different sets of water drops is obtained from experiments. Then several factors, which may affect the electric field analysis of water drop corona, are studied by numerical calculation on computer. Calculation is mainly on a 2-D model. However, a 3-D model is also used to study the effect of water drops distributed in space.
Keywords :
Composite insulation , Corona , electric fields , numericalanalysis.
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Serial Year :
2005
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Record number :
400904
Link To Document :
بازگشت