• Title of article

    Worst-case identification of touch voltage and stray current of DC railway system using genetic algorithm

  • Author/Authors

    Chang، نويسنده , , C.S.; Tian، نويسنده , , L.F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    7
  • From page
    570
  • To page
    576
  • Abstract
    The problem of reducing the touch voltage and stray current in DC railways is multiobjective and conficting. It is affected by many factors such as the earthing and bonding design, as well as the normal and failure operating conditions. An approach of genetic algorithm.based multiobjective optimisation is proposed to identify the worst-case touch voltage and stray current in MRT systems. A two-step design scheme is formulated to represent both the normal and the failure conditions. The method of Pareto-optimal sets is developed to best improve the touch voltages and stray current integral for the normal condition. The decision-maker is given a powerful tool for pickmg the most appropriate earthing and bonding design from the set, and for identifying the worstcase performance from the list of credible failure conditions. Simulation results are presented whch demonstrate the effectiveness of the proposed approach in fulfilling the design objectives.
  • Journal title
    IEE Proceedings Electric Power Applications
  • Serial Year
    1999
  • Journal title
    IEE Proceedings Electric Power Applications
  • Record number