Title of article :
Continuous-conduction-mode boost converter with reduced reverse-recovery loss
Author/Authors :
Do، نويسنده , , H.-L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
A continuous-conduction-mode boost converter with reduced reverse-recovery loss is
proposed. By utilising the auxiliary winding of the boost inductor, two additional rectifiers and an
auxiliary inductor, the current decrease rates (di/dt) of the boost output rectifier and two additional
rectifiers are slowed down to reduce the reverse-recovery loss. Experimental results for a 600W
power factor correction AC/DC boost converter at a constant switching frequency of 100kHz are
obtained to show the performance of the proposed converter. It is shown that a significant
efficiency improvement is achieved.
Journal title :
IEE Proceedings Electric Power Applications
Journal title :
IEE Proceedings Electric Power Applications