Title of article :
Load and resistance factor design of composite columns
Author/Authors :
Jane E. Lundberg ، نويسنده , , Theodore V. Galambos، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
Test capacities of composite concrete-encased steel profile and concrete-filled tube columns and beam-columns are
compared with predictions of the design model of the American Institute of Steel Construction Load and Resistance Factor
Design criteria. Some 300 tests were examined. It was found that the design model is conservative, but that the scatter of the
tests with respect to the AISC design model is also high. A first-order second-moment reliability study revealed that the
concrete-encased members exceeded the target reliability index in the design specification, but that the concrete-filled tubes
had an inadequate reliability index when compared to the target value. It is recommended that both a better design model
and further tests are needed to arrive at satisfactory design criteria. Copyright
Keywords :
Design codes , stability , Reliability , Beam-columns , Evaluation of experiments , columns , Composite design
Journal title :
Structural Safety
Journal title :
Structural Safety