Abstract :
Abstract-The dynamic safety system (DSS) is a computer based reactor protection
system that has dynamic self-testing feature and fail-safe nature inherently.
The dynamic self-testing and fail-safe features provide a high level of
reliability and low spurious trip rate. The time and human efforts maintaining
the system can also be reduced by virtue of those features. In order to apply
the DSS for PWR, however, some modification is required because there exist
many differences between PWR and AGR for which the DSS was first tested
and installed. These differences are trip algorithms, monitored parameters, trip
logics, and other conditions. In this work, the DSS algorithm is modified for
PWR. The modified DSS has several new features which are required for
applying DSS technology to PWR. Then, the modified DSS is implemented in
a programmable logic controller (PLC) and tested. It is shown that, from the
results, the modified DSS generates correct output in all test cases