• Title of article

    The effect of tube rupture location on the consequences of multiple steam generator tube rupture event

  • Author/Authors

    Ji Hwan Jeong، نويسنده , , Young Chul Kweon، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    18
  • From page
    1809
  • To page
    1826
  • Abstract
    A multiple steam generator tube rupture (MSGTR) event has never occurred in the commercial operation of nuclear reactors while single steam generator tube rupture (SGTR) events are reported to occur every 2 years. As there has been no occurrence of a MSGTR event, the understanding of transients and consequences of this event is very limited. In this study, a postulated MSGTR event in an advanced power reactor 1400 (APR1400) is analyzed using the thermal-hydraulic system code, MARS1.4. The APR1400 is a two-loop, 3893 MWt, PWR proposed to be built in 2010. The present study aims to understand the effects of rupture location in heat transfer tubes following a MSGTR event. The effects of five tube rupture locations are compared with each other. The comparison shows that the response of APR1400 allows the shortest time for operator action following a tube rupture in the vicinity of the hot-leg side tube sheet and allows the longest time following a tube rupture at the tube top. The MSSV lift time for rupture at the tube-top is evaluated as 24.5% larger than that for rupture at the hot-leg side tube sheet.
  • Journal title
    Annals of Nuclear Energy
  • Serial Year
    2002
  • Journal title
    Annals of Nuclear Energy
  • Record number

    405721