Title of article :
Heat removal performance of auxiliary cooling system for the high temperature engineering test reactor during scrams
Author/Authors :
Takeshi Takeda، نويسنده , , Yukio Tachibana، نويسنده , , Tatsuo Iyoku، نويسنده , , Satsuki Takenaka، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
20
From page :
811
To page :
830
Abstract :
The auxiliary cooling system of the high temperature engineering test reactor (HTTR) is employed for heat removal as an engineered safety feature when the reactor scrams in an accident when forced circulation can cool the core. The HTTR is the first high temperature gas-cooled reactor in Japan with reactor outlet gas temperature of 950 °C and thermal power of 30 MW. The auxiliary cooling system should cool the core continuously avoiding excessive cold shock to core graphite components and water boiling of itself. Simulation tests on manual trip from 9 MW operation and on loss of off-site electric power from 15 MW operation were carried out in the rise-to-power test up to 20 MW of the HTTR. Heat removal characteristics of the auxiliary cooling system were examined by the tests. Empirical correlations of overall heat transfer coefficients were acquired for a helium/water heat exchanger and air cooler for the auxiliary cooling system. Temperatures of fluids in the auxiliary cooling system were predicted on a scram event from 30 MW operation at 950 °C of the reactor outlet coolant temperature. Under the predicted helium condition of the auxiliary cooling system, integrity of fuel blocks among the core graphite components was investigated by stress analysis. Evaluation results showed that overcooling to the core graphite components and boiling of water in the auxiliary cooling system should be prevented where open area condition of louvers in the air cooler is the full open.
Journal title :
Annals of Nuclear Energy
Serial Year :
2003
Journal title :
Annals of Nuclear Energy
Record number :
405793
Link To Document :
بازگشت