Title of article :
Reliability analysis of shutdown system
Author/Authors :
C. Senthil Kumar، نويسنده , , A. John Arul، نويسنده , , Om Pal Singh، نويسنده , , K. Suryaprakasa Rao، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
This paper presents the results of reliability analysis of Shutdown System (SDS) of Indian Prototype Fast Breeder Reactor. Reliability analysis carried out using Fault Tree Analysis predicts a value of 3.5 × 10−8/de for failure of shutdown function in case of global faults and 4.4 × 10−8/de for local faults. Based on 20 de/y, the frequency of shutdown function failure is 0.7 × 10−6/ry, which meets the reliability target, set by the Indian Atomic Energy Regulatory Board. The reliability is limited by Common Cause Failure (CCF) of actuation part of SDS and to a lesser extent CCF of electronic components. The failure frequency of individual systems is <1 × 10−3/ry, which also meets the safety criteria. Uncertainty analysis indicates a maximum error factor of 5 for the top event unavailability.
Journal title :
Annals of Nuclear Energy
Journal title :