Title of article :
Analysis of the cooling capability of steam generators during the loss of residual heat removal system at midloop operation with closed primary system
Author/Authors :
Cesar Queral، نويسنده , , Isaac Gonzalez، نويسنده , , Antonio Exposito، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
14
From page :
1102
To page :
1115
Abstract :
Loss of residual heat removal system (RHRS) at midloop operation is one of the most significant core damage risk contributor at low power and shutdown conditions. During this kind of transients the reflux-condensation is one of the cooling mechanisms anticipated in the abnormal procedure of loss of RHRS at midloop level. In this sense, several simulations of loss of the RHRS with closed primary system with the TRACE V4.160 code have been performed considering different availability of steam generators. The present study aims to analyze the thermal-hydraulic behavior after the loss of RHRS at midloop conditions with the reflux-condensation as the only cooling mechanism available and to investigate the capability of this cooling mechanism. The simulation results show that one steam generator is sufficient to remove core decay heat of 11 MWobtaining an equilibrium pressure, but the core uncovery depends on the number of steam generators operating. Finally, an analysis of the abnormal procedure and the event trees of the loss of RHRS sequences at midloop operation has been performed taking into account the results obtained in the simulation with TRACE.
Journal title :
Annals of Nuclear Energy
Serial Year :
2006
Journal title :
Annals of Nuclear Energy
Record number :
406220
Link To Document :
بازگشت