SCALE analysis of CLAB decay heat measurements for LWR spent fuel assemblies
Author/Authors
Germina Ilas، نويسنده , , Ian C. Gauld، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
12
From page
37
To page
48
Abstract
A set of decay heat measurements for spent fuel assemblies recently carried out at the Swedish central interim storage facility for spent fuel, CLAB, was analyzed with the SCALE code system. The measurements include a variety of light water reactor assemblies that cover a large burnup range – up to 51 GWd/MTU – and a cooling time domain of interest to spent fuel storage and transportation applications. The results of the analysis show a good agreement between measured and predicted decay heat, with the calculated decay heat in general within the range of the uncertainty of the measured value. The effect of various assembly data on the calculated decay heat is analyzed and discussed. Uncertainties that may arise from various approaches and assumptions in the computational model are identified and examined.