• Title of article

    Commissioning of the ATLAS thermal-hydraulic integral test facility

  • Author/Authors

    Yeon-Sik Kim، نويسنده , , Ki-Yong Choi، نويسنده , , Hyeon-Sik Park، نويسنده , , Hyeong Seok Cho، نويسنده , , Bok-Deug Kim، نويسنده , , Nam-Hyeon Choi، نويسنده , , Won Pil Baek، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    1791
  • To page
    1799
  • Abstract
    KAERI recently constructed a new thermal-hydraulic integral test facility for advanced pressurized water reactors (PWRs) – ATLAS. The ATLAS facility has the following characteristics: (a) 1/2-height&length, 1/288-volume, and full pressure simulation of APR1400, (b) maintaining a geometrical similarity with APR1400 including 2(hot legs) × 4(cold legs) reactor coolant loops, direct vessel injection (DVI) of emergency core cooling water, integrated annular downcomer, etc., (c) incorporation of specific design characteristics of OPR1000 such as cold leg injection and low-pressure safety injection pumps, (d) maximum 10% of the scaled nominal core power. The ATLAS will mainly be used to simulate various accident and transient scenarios for evolutionary PWRs, OPR1000 and APR1400: the simulation capability of broad scenarios including the reflood phase of a large-break loss-of-coolant accident (LOCA), small-break LOCA scenarios including DVI line breaks, a steam generator tube rupture, a main steam line break, a feed line break, a mid-loop operation, etc. The ATLAS is now in operation after an extensive series of commissioning tests in 2006.
  • Journal title
    Annals of Nuclear Energy
  • Serial Year
    2008
  • Journal title
    Annals of Nuclear Energy
  • Record number

    406551