Title of article :
Flexural Capacity of Glass FRP Strengthened Concrete Masonry Walls
Author/Authors :
III، H. R. Hamilton نويسنده , , Dolan، C. W. نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
Fiber-reinforced polymers (FRP) can provide a strengthening alternative for unreinforced and underreinforced masonry. The ease with which FRP can be installed on the exterior of a masonry wall makes this form of strengthening attractive to the owner, considering both reduced installation cost and down time of the occupied structure. Six unreinforced concrete masonry walls (four at 1.8 m tall and two at 4.7 m tall) were tested in out-of-plane flexure up to capacity. The walls were strengthened with glass FRP composite composed of unidirectional E-glass fabric with an epoxy matrix. The composite was adhered to the surface of the masonry using the same epoxy with the fibers oriented perpendicular to the bed joints. General flexural strength design equations are presented and compared with the results of the testing. It was found that the equations overpredicted the actual capacity of the test specimens by no more than 20%.
Keywords :
A. Organic compounds , A. Superconductors , D. Phase transitions , D. Spin-density waves
Journal title :
JOURNAL OF COMPOSITES FOR CONSTRUCTION
Journal title :
JOURNAL OF COMPOSITES FOR CONSTRUCTION