Title of article :
Contamination of indoor air by toxic soil vapours: a screening risk assessment model
Author/Authors :
C. C. Ferguson، نويسنده , , B. A. Kiselman and V. V. Krylov، نويسنده , , P. T. McGrath، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
9
From page :
375
To page :
383
Abstract :
A simple steady-state model is derived for estimating the concentration of vapour-phase contaminants in indoor air, given the contaminant concentration in the soil. The model includes the key mechanisms of transport and dispersion—contaminant partitioning into the soil-vapour phase, molecular diffusion, suction flow, and ventilation rate. It is shown that indoor air concentrations are largely controlled by two variables: soil permeability, and the half-life for contaminant removal from soil. A worked example shows the effect of these two variables on the concentration of benzene in soil that would give rise to a concentration of benzene in indoor air of 5 ppb (the recently proposed U.K. Air Quality Standard).
Journal title :
Building and Environment
Serial Year :
1995
Journal title :
Building and Environment
Record number :
408018
Link To Document :
بازگشت