Title of article :
Derivation of capture efficiency of kitchen range hoods in a confined space
Author/Authors :
Yuguo Li، نويسنده , , Angelo Delsante، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
8
From page :
461
To page :
468
Abstract :
An existing derivation of capture efficiency of a kitchen range hood in a confined flow system, based on a two-zone mixing model, is shown to be inconsistent and inadequate. A new derivation is proposed, which shows that the capture efficiency equals the ratio of captured flow rate to the total plume flow rate at the front canopy height. The new capture efficiency equals the direct capture efficiency, if we assume that the hood captures contaminant directly from the source as efficiently as it captures contaminant that is entrained from the room.
Journal title :
Building and Environment
Serial Year :
1996
Journal title :
Building and Environment
Record number :
408082
Link To Document :
بازگشت