• Title of article

    Carbon monoxide transport in an enclosed room with sources from a water heater in the adjacent balcony

  • Author/Authors

    W.R. Chang، نويسنده , , C.L. Cheng، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    10
  • From page
    861
  • To page
    870
  • Abstract
    This paper has presented a computational analysis of carbon monoxide (CO) concentration inside a typical enclosed room of a residential building in Taiwan. CO is produced from a house-used natural gas water heater installed in the balcony. It is then diffused into the adjacent bedroom, which often causes serious poisoning accidences. A general-purpose computational fluid dynamics (CFD) code is employed to predict the CO concentration and airflow fields inside a three-dimensional (3D) modeled house. The variation of CO concentration was simulated under different scenarios of vent air flow rates and exit openings. It was found that under the ventilation conditions of V>0.0003 m/s, the levels of CO concentration in the bedroom is significantly decreased due to the entrainment of fresh air into the bedroom from the inside door. The present results could be used as a base for ventilation design for enclosed rooms, aiming at a proper ventilation system selection for avoiding the CO poisoning.
  • Keywords
    CARBON MONOXIDE , transport , Water heater , poisoning
  • Journal title
    Building and Environment
  • Serial Year
    2008
  • Journal title
    Building and Environment
  • Record number