Title of article
Parabolic trough collector system for low temperature steam generation: Design and performance characteristics
Author/Authors
Soteris Kalogirou، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
19
From page
1
To page
19
Abstract
The collectorʹs performance is tested according to Ashrae Standard 93, 19861. The collectorʹs efficiency and incidence-angle modifier are measured. The test slope and intercept are found to be 0.387 and 0.638 respectively. The collectorʹs time constant is less than one minute and the collectorʹs acceptance angle obtained from the test is ±0.5°, which in combination with the tracking mechanism maximum error (± 0.2°) implies that the system works continuously at almost maximum possible efficiency.
Journal title
Applied Energy
Serial Year
1996
Journal title
Applied Energy
Record number
414195
Link To Document