• Title of article

    Parabolic trough collector system for low temperature steam generation: Design and performance characteristics

  • Author/Authors

    Soteris Kalogirou، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    19
  • From page
    1
  • To page
    19
  • Abstract
    The collectorʹs performance is tested according to Ashrae Standard 93, 19861. The collectorʹs efficiency and incidence-angle modifier are measured. The test slope and intercept are found to be 0.387 and 0.638 respectively. The collectorʹs time constant is less than one minute and the collectorʹs acceptance angle obtained from the test is ±0.5°, which in combination with the tracking mechanism maximum error (± 0.2°) implies that the system works continuously at almost maximum possible efficiency.
  • Journal title
    Applied Energy
  • Serial Year
    1996
  • Journal title
    Applied Energy
  • Record number

    414195